site stats

Terbium cryptate labeling kit

WebEuropium Cryptate labeling kit. The macrocycle structure of Europium trisbipyridine Cryptate (Eu-TBP-K) allows them to be derivatized by a variety of reactive functions that can target the best represented groups on proteins or oligonucleotides. Initially, both the Cryptate and the target molecule had to be activated for a covalent conjugation ... WebJun 16, 2024 · Both red acceptors can be coupled with either a europium or terbium cryptate. Terbium donors can be additionally combined with green-emitting acceptors …

Labeling Kits - Deciphering the interactome - By universe …

Web更多其他产品(药物杂质、食品检测标品、农兽残检测标品、环境及工业检测标品标液、维生素、胆汁酸、氨基酸、糖代谢、类花生酸、肉碱、脂肪酸、植物激素、动物激素、儿茶酚胺、植物提取物、修饰性peg、微球、分子生化、细胞、蛋白抗体)请联系上海赛可锐生物: 许经理 手机15900491054( WebBlenders and Accessories; Blenders and Homogenizer; Bottle Roller Accessories; Bottle Rollers; Grinding Mills; Hotplate and stirrer Accessories; Magnetic Stir Bars fall 8lak https://montoutdoors.com

IP-One - Gq KIT - PerkinElmer

WebTerbium Cryptate labeling kit 1. Kit description and intended use The structure of Lumi4®-Terbium Cryptate (Lumi4®-Tb-K) allows it to be derivatized by a variety of reactive functions that can target the best represented groups on proteins or oligonucleotides. WebMar 30, 2024 · Brenntag is the global market leader in chemical and ingredients distribution. The Germany based international company manages complex supply chains for both … WebThe best donors are cryptates, comprised of rare-earth complexes (europium or terbium) with a lanthanide embedded in a macrocycle1. They exhibit long-lived fluorescence, stability, and robustness necessary to survive many assay conditions. fall 934 bgb

ffice Europium Cryptate labeling kit - PerkinElmer

Category:Tau aggregation HTRF kit Cisbio - PerkinElmer

Tags:Terbium cryptate labeling kit

Terbium cryptate labeling kit

HTRF: A technology tailored for drug discovery - a review of ...

WebMar 1, 2006 · A new fluorescent labeled compound of microcystin-LR with terbium cryptate was obtained by initial conjugation of microcystins-LR with aminoethanethiol followed by the reaction with the ester... WebMay 28, 2009 · HTRF has also been utilized as an alternative method for bioprocess monitoring. The first-generation HTRF technology, which uses Europium cryptate as a …

Terbium cryptate labeling kit

Did you know?

WebThe Cryptate labeling kit is suitable for quick, easy labeling of peptides, proteins, and oligonucleotides with Terbium cryptate. This kit is designed for very small-volume fast … WebFlexStation® 3 Multi-Mode Microplate Reader. Figure 1. HTRF-compatible SpectraMax Multi-Mode Readers. SpectraMax i3/i3x and Paradigm readers can be equipped with …

WebOct 17, 2024 · Cryptate structures, in which either the europium or the terbium ion is tightly embedded in its macrocycle, resist harsh assay conditions or additives: presence of … WebThe Cryptate labeling kit is suitable for quick, easy labeling of peptides, proteins, and oligonucleotides with Europium cryptate. This kit is designed for very small-volume fast labeling needs, such as determining the best antibody among several antibodies available for HTRFassay development.

WebMar 1, 2006 · A new fluorescent labeled compound of microcystin-LR with terbium cryptate was obtained by initial conjugation of microcystins-LR with aminoethanethiol followed by … WebThe Cryptate labeling kit is suitable for quick, easy labeling of peptides, proteins, and oligonucleotides with Terbium cryptate. This kit is designed for very small-volume fast …

WebApr 1, 2015 · Europium Cryptate Labeling Antibodies (100–200 µg) in 0.1 M sodium hydrogen carbonate/PBS were incubated with trisbipyridine-Eu 3+ cryptate-N-hydroxysuccinimide (NHS) (Cisbio, Codolet, France) at a cryptate to protein ratio of 13–14:1 (pmol) for 100 min at room temperature in the dark.

WebProduct Size Part# SIRT 1 kit 1,000 tests 64SI1PEB 20,000 tests 64SI1PEC Ubiquitin Toolbox Eu-cryptate labeled ubiquitin, is used to create homogeneous assays for monitoring mono-, auto-, and polyubiquitination of proteins. These highly sensitive assays are easily miniaturized for reduced enzyme consumption and increased throughput. fallabanWebdetermine specificity. By developing kinase assays that employ either a terbium- or a europium-based time-resolved fluores-cence resonance energy transfer (TR-FRET) readout, one can take advantage of the distinct emission properties of these labels to develop assays for 2 kinases that can be performed simultaneously in the same well. hk dollar to bangladeshi takahk domain buyWebTerbium Cryptate Labeling kit 1.2 Use With the exception of products specifically labeled for In Vitro Diagnostic use, all other products are for laboratory research use only and are not intended for human or animal diagnostics, therapeutics, or other clinical uses. 1.3 Manufacturer / Supplier identification: Cisbio Bioassays falla banco azteca hoyWebMar 28, 2024 · Three labeling kits tailored for biomolecule labeling and straightforward development of time-resolved fluorescence resonance … hk domain namesWebMar 15, 2016 · Antibody production and terbium cryptate labeling The anti-His antibody 4F8 was generated after intraperitoneal and subcutaneous (IP/SC) immunizations of Balb/c mice (Charles River Laboratories International, Wilmington, MA, USA) five times weekly with 10 μg of recombinant antigen A, containing a histidine tag (×6) at its C terminus, per ... hk domain nameWebOriCell®外泌体提取试剂盒(细胞培养上清)采用独特的分离技术,可以快速从细胞培养上清中获得大量的外泌体颗粒,可用于细胞学、动物学等相关实验中。 产品信息: 产品规格 货号 体积 OriCell® Exosomes Extraction Kit For Cell Culture .hk domain name