Synthes 7.3 cannulated screws
WebThis site is published by the DePuy Synthes Companies, which are solely responsible for its content. This site is intended for use by residents of Latin America, Europe, Middle East … WebSynthes Screw Reference Chart Reference Chart Screws, Drill Bits, Taps ... Thread Diameter 1.0 1.3 1.5 2.0 2.4 2.7 3.5 4.0 4.5 6.5 Cortex, self-tapping Cortex Pelvic Shaft Cortex …
Synthes 7.3 cannulated screws
Did you know?
Webtactile feedback for inserting cannulated screws is diminished. This may explain the trend toward a higher torque for non-cannulated screws and the greater standard deviation in the load to failure for both 6.5-mm and 7.3-mm cannulated screws in our study (Table 2). Cannulated screws are easier to use; once the guidewire is deployed in the correct WebIf planning to countersink, this should be done prior to inserting the cannulated screw measuring device. 8 Synthes 6.5 mm and 7.3 mm Cannulated Screws Technique Guide. 4. Insert screw. Instruments. 310.495. 310.63. 314.05. 314.11. 314.23. 7.3 mm Cannulated Drill Bit. 5.0 mm Cannulated Drill Bit . Cannulated Hexagonal Screwdriver. Holding Sleeve
WebCatalog Number: 105.185. Set includes implants, instruments and storage for 7.3 mm Cannulated Screws. CLICK HERE for complete list of system components. See close-up … WebSlipped Capital Femoral Epiphysis (SCFE) Screw System Surgical Technique DePuy Synthes 13 5 Insert screw Instrument 03.207.005 Screwdriver Stardrive, T40, length 350.5 mm …
WebInsertion of the cannulated screws. To prepare the path for the core diameter of the screws, drill over the wires with a 3.6 mm cannulated drill bit. Then insert three 7.0 mm or 7.3 mm cannulated cancellous screws over the wires. In younger patients with dense cancellous bone, the cannulated tap may be necessary to precut the thread. http://www.cambridgeorthopaedics.com/easytrauma/classification/commonfiles/Synthes%20screws.pdf
http://synthes.vo.llnwd.net/o16/LLNWMB8/INT%20Mobile/Synthes%20International/Product%20Support%20Material/legacy_Synthes_PDF/182988.pdf
WebDiameter: 0.11" (2.8 mm) Overall length: 11.81" (30 cm) Threaded. Trocar point tip. Cobalt-base Alloy (L-605) L-605 is a cobalt-base implant material (ASTM F 90 specification) that contains 20% chromium, 15% tungsten, 10% nickel, balance cobalt.The alloy is not a stainless steel. The following guide wires are manufactured from L-605 alloy ... thor 337 go collecthttp://synthes.vo.llnwd.net/o16/llnwmb8/us%20mobile/synthes%20north%20america/product%20support%20materials/technique%20guides/dsustrm02160831%20rev%20c.pdf ultimate weight lossWebNov 20, 2014 · 6. 2. Option: Insert guide wires in parallel. (only for cannulated screws 4.5/6.5/7.0/7.3) Slide the non-adjustable guide sleeve (1) of the parallel guide. over the already inserted guide wire. Move the (adjustable) guide sleeve (2) to the desired position and tighten the nut. Insert the second guide wire. ultimate weight loss program chef ajWebDePuy Synthes 7.0 mm and 7.3 mm Cannulated Screws, DePuy Synthes 1.5 mm Headless Compression Screws, DePuy Synthes 2.4 mm Headless Compression Screws, DePuy Synthes 3.0 mm Headless Compression Screws, DePuy Synthes 4.5 mm and 6.5 mm Headless Compression Screw (K161616) Device Description ultimate weight solutionWeb6.5/7.3 cannulated screw system with SCFE specific instrumentation. Read More. Cannulated Screws. Comprehensive range of screws in short, medium and fully threaded from 2.5mm-7.3mm. Read More. PediFrag – Wrist Fusion. ultimate weight loss dietWebDePuy Synthes Stainless Steel Self-Tapping Cannulated Screw, 7.3 dia. x 135 mm Length, 32 mm ... Screw, 7.3 dia. x 135 mm Length, Stainless Steel, 32 mm Thread ... Core Diameter, 4.8 mm Shaft Diameter, 2.9 mm Cannulation Diameter, 8.2 mm Head Diameter, Self-Tapping, Self-Drilling, Cannulated. $119.00 /Each . Notify me when the price drops ... thor 33.5 palazzoWebOur e-learning platform contains high resolution images and a certified CME of the Slipped upper femoral epiphysis : Percutaneous pinning with Synthes 73 mm cannulated screws surgical procedure. Slipped capital femoral epiphysis (SCFE, SUFE) has an incidence of between 5-10 per 100,000 children per year, generally occurring during the adolescent … thor 3270